Unidrive SP
|
|
|
|
|
Selection
|
Normal
Duty |
Heavy
Duty |
Typical
Motor Power |
Continuous
Output Current |
Max.
Output Current |
Typical
Motor Power |
Continuous
Output Current |
Maximum
Output Current |
Model
Reference |
Frame
Size |
Supply
Voltage & Motor Power Rated Voltage |
(kW) |
(hp) |
In
(A) |
Open
Loop (A) |
(kW) |
(hp)
|
In
(A) |
Open
Loop (A) |
Closed
Loop (A) |
SP1201
|
1 |
200 to 240V
± 10%
kW at 220V
hp at 230V
|
1.1
|
1.5
|
5.2
|
5.7
|
0.8
|
1.0
|
4.3
|
6.5
|
7.5
|
SP1202
|
1.5
|
2.0
|
6.8
|
7.5
|
1.1
|
2.0
|
5.8
|
8.7
|
10.2
|
SP1203
|
2.2
|
3.0
|
9.6
|
10.6
|
1.5
|
2.0
|
7.5
|
11.3
|
13.1
|
SP1204
|
3.0
|
3.0
|
11.0
|
12.1
|
2.2
|
3.0
|
10.6
|
15.9
|
18.6
|
SP2201
|
2 |
4.0
|
5.0
|
15.6
|
17.1
|
3.0
|
3.0
|
12.6
|
18.9
|
22.1
|
SP2202
|
5.5
|
7.5
|
22.0
|
24.2
|
4.0
|
5.0
|
17.0
|
25.5
|
29.8
|
SP2203 |
7.5 |
10.0 |
28.0 |
30.8 |
5.5 |
7.5 |
25.0 |
37.5 |
43.8 |
SP3201
|
3 |
11.0
|
15.0
|
42.0
|
46.2
|
7.5
|
10.0
|
31.0
|
46.5
|
54.3
|
SP3202
|
15.0
|
20.0
|
54.0
|
59.4
|
11.0
|
15.0
|
42.0
|
63.0
|
73.5
|
SP1401
|
1 |
380 to 480V
± 10%
kW at 400V
hp at 460V
|
1.1
|
1.5
|
2.8
|
3.1
|
0.8
|
1.0
|
2.1
|
3.2
|
3.7
|
SP1402
|
1.5
|
2.0
|
3.8
|
4.2
|
1.1
|
2.0
|
3.0
|
4.5
|
5.3
|
SP1403
|
2.2
|
3.0
|
5.0
|
5.5
|
1.5
|
3.0
|
4.2
|
6.3
|
7.4
|
SP1404
|
3.0
|
5.0
|
6.9
|
7.6
|
2.2
|
3.0
|
5.8
|
8.7
|
10.2
|
SP1405
|
4.0
|
5.0
|
8.8
|
9.7
|
3.0
|
5.0
|
7.6
|
11.4
|
13.3
|
SP1406 |
5.5 |
7.5 |
11.0 |
12.1 |
4.0 |
5.0 |
9.5 |
14.3 |
16.6 |
SP2401
|
2 |
7.5
|
10.0
|
15.3
|
16.8
|
5.5
|
10.0
|
13.0
|
19.5
|
22.8
|
SP2402
|
11.0
|
15.0
|
21.0
|
23.1
|
7.5
|
10.0
|
16.5
|
24.8
|
28.9
|
SP2403
|
15.0
|
20.0
|
29.0
|
31.9
|
11.0
|
20.0
|
25.0
|
37.5
|
43.8
|
SP3401
|
3 |
18.5
|
25.0
|
35.0
|
38.5
|
15.0
|
25.0
|
32.0
|
48.0
|
56.0
|
SP3402
|
22.0
|
30.0
|
43.0
|
47.3
|
18.5
|
30.0
|
40.0
|
60.0
|
70.0
|
SP3403
|
30.0
|
40.0
|
56.0
|
61.6
|
22.0
|
30.0
|
46.0
|
69.0
|
80.5
|
SP3501
|
3
|
500 to 575V
± 10%
kW at 575V
hp at 575V
|
3.0
|
5.0
|
5.4
|
5.9
|
2.2
|
3.0
|
4.0
|
6.0
|
7.0
|
SP3502
|
4.0
|
5.0
|
6.1
|
6.7
|
3.0
|
3.0
|
5.4
|
8.1
|
9.5
|
SP3503 |
5.5 |
7.5 |
8.3 |
9.1 |
3.0 |
5.0 |
6.1 |
9.2 |
10.7 |
SP3504
|
7.5
|
10.0
|
11.0
|
12.1
|
5.5
|
7.5
|
9.5
|
14.3
|
16.6
|
SP3505
|
11.0
|
15.0
|
16.0
|
17.6
|
7.5
|
10.0
|
12.0
|
18.0
|
21.0
|
SP3506
|
15.0
|
20.0
|
22.0
|
24.2
|
11.0
|
15.0
|
18.0
|
27.0
|
31.5
|
SP3507
|
18.5
|
25.0
|
27.0
|
29.7
|
15.0
|
20.0
|
22.0
|
33.0
|
38.5
|
All Unidrive SP modules have
optional footprint filters for applications not met with
standard on board filters
|
|
|
|
Normal Duty
(open loop) |
Suitable for most applications,
current overload is set at 110% for 60s. Where motor rated
current is less than the drive rated continuous current, higher
overloads are achieved.
|
Heavy Duty
(open loop) |
Suitable for more demanding
applications, current overload is set at 150% for 60s. Where
motor rated current is less than the drive rated continuous
current, higher overloads ( 200% or greater) are achieved.
|
Heavy Duty
(closed loop,
servo) |
Suitable for demanding
applications where high dynamic shaft performance is necessary,
current overload is set at 175% for 20s. Where motor rated
current is less than the drive rated continuous current, higher
overloads (200% or greater) are achieved.
|
|
|
|
|
|
|
"New"
Size Zero |
|
Selection
|
Normal
Duty |
Heavy
Duty |
Typical
Motor Power |
Continuous
Output Current |
Max.
Output Current |
Typical
Motor Power |
Continuous
Output Current |
Model
Reference |
Frame
Size |
Supply
Voltage & Motor Power Rated Voltage |
(kW) |
(hp) |
In
(A) |
Open
Loop (A) |
(kW) |
(hp)
|
In
(A) |
SP0201
|
0 |
200 to 240V
± 10%
Single Phase
kW at 220V
hp at 230V
|
-
|
-
|
-
|
-
|
0.37
|
0.5
|
2.2
|
SP0202
|
-
|
-
|
-
|
-
|
0.55
|
0.75
|
3.1
|
SP0203
|
-
|
-
|
-
|
-
|
0.75
|
1
|
4
|
SP0204
|
-
|
-
|
-
|
-
|
1.1
|
1.5
|
5.7
|
SP0205
|
-
|
-
|
-
|
-
|
1.5
|
2
|
7.5
|
|
SP0201
|
0 |
200 to 240V
± 10%
kW at 220V
hp at 230V
|
-
|
-
|
-
|
-
|
0.37
|
0.5
|
2.2
|
SP0202
|
-
|
-
|
-
|
-
|
0.55
|
0.75
|
3.1
|
SP0203
|
-
|
-
|
-
|
-
|
0.75
|
1
|
4
|
SP0204
|
-
|
-
|
-
|
-
|
1.1
|
1.5
|
5.7
|
SP0205
|
-
|
-
|
-
|
-
|
1.5
|
2
|
7.5
|
SP0401
|
0
|
380 to480V
± 10%
kW at 400V
hp at 460V
|
-
|
-
|
-
|
-
|
0.37
|
0.5
|
1.3
|
SP0402
|
-
|
-
|
-
|
-
|
0.55
|
0.75
|
1.7
|
SP0403 |
-
|
-
|
-
|
-
|
0.75 |
1 |
2.1 |
SP0404
|
-
|
-
|
-
|
-
|
1.1
|
1.5
|
3
|
SP0405
|
-
|
-
|
-
|
-
|
1.5
|
2
|
4.2
|
All Unidrive SP modules have
optional footprint filters for applications not met with
standard on board filters
|
|
|
|
|
|
AC Drive / Home / Contact
Us / Products / Service
/ Sales /Supported
Product / Powertec Support
/ Serviced Products / Feedback
Microcon
Technologies Inc.
1105
Crestlawn Drive, Unit # D8 & D9
Mississauga,
Ontario L4W 1A7 Canada
Tel:
(905) 602-4770
Fax:
(905) 602-4779
e-mail:
[email protected]
Website:
www.microcontechnologies.com